Steam from a humidifier electric gas steam to steam when the steam for humidification is generated locally there are two methods normally used to handle the condensate.
Clean steam condensate cooler.
Introduction to steam and condensate systems boiler operation accreditation scheme boas boas renewal.
Armstrong cc 5 cc 12 cc 25 and cc 40 condensate coolers.
With information found on the sample cooler inquiry questionnaire a sample cooler can be provided for applications such as steam boiler water chemical processes and others in high pressure and high temperature ranges.
Sc20 sample coolers and systems.
Clean steam must be free of contaminants at the point of use.
We use cookies to give you the best experience on our website.
This steam trap is therefore acting mostly as a steam cooler wasting steam from the steam main.
For instance steam sample coolers can provide condensate.
Sample coolers are used to cool fluids or vapors to a point they can be safely handled for collection and analysis.
Condensate temperature can be 180 f saturated pure steam is often at pressures of 30 60 psig temperatures between 274 307 f saturated plant steam is often at pressures around 150 psig temperature of 366 f superheated steam can be at much higher temperatures serious injuries including burns and death are possible.
The condensate flows from the p trap to a condensate pump or to a drain cooler and finally is wasted down the drain.
Spirax sarco stainless steel sample coolers allows you to sample boiler water safely and accurately.
Cemline blow down condensate coolers are designed to receive blow down from a steam boiler flash the blow down to steam and cool the condensate going to drain.
Condensate should always be drained from the bottom of the steam line in low sections of pipe and at changes in direction such as a 90 degree turn.
Ssc20 sanitary sample cooler.
Note the nice insulation job however.
Chemical and microbial contaminants can enter steam systems in a variety of ways and in the design of clean steam systems this must be avoided.
Clean steam condensate and heat recovery systems.
High water cut off in some unusual situations it is possible for the feedwater to fail which could cause the unfired steam generator to fill with water and flood the entire system.
Armstrong s condensate cooler mixes hot condensate or hot water with a cold water supply to reduce the temperature to acceptable drain temperatures as required by city and state codes.